High Power FM Transmitter Price: CORTEX 10 kW, 20 kW and 50 kW
CORTEX from 5 kW to 100 kW, built on 2.5 kW amplifier modules
Keep broadcasting when an RF module fails: CORTEX scales from 5 to 100 kW with independent CELL amplifiers, oversized unbalanced loads and module-by-module remote diagnostics.
CORTEX list prices
| Model | Power | Amplifier modules (2.5 kW) | List price |
|---|---|---|---|
| CORTEX 5/2 | 5 kW | 2 | €27,000 |
| CORTEX 7.5/3 | 7.5 kW | 3 | €34,000 |
| CORTEX 10/4 | 10 kW | 4 | €45,000 |
| CORTEX 12.5/5 | 12.5 kW | 5 | €51,000 |
| CORTEX 15/6 | 15 kW | 6 | €62,000 |
| CORTEX 17.5/7 | 17.5 kW | 7 | €77,000 |
| CORTEX 20/8 | 20 kW | 8 | €84,000 |
| CORTEX 22.5/9 | 22.5 kW | 9 | €89,000 |
| CORTEX 25/10 | 25 kW | 10 | €96,000 |
| CORTEX 30/12 | 30 kW | 12 | €115,000 |
| CORTEX 35/14 | 35 kW | 14 | €135,000 |
| CORTEX 40/16 | 40 kW | 16 | €150,000 |
| CORTEX 45/18 | 45 kW | 18 | €165,000 |
| CORTEX 50/20 | 50 kW | 20 | €180,000 |
| CORTEX above 50 kW | up to 100 kW | on request |
Indicative list prices in euro, ex works Italy, VAT and transport excluded. Every price must be confirmed with a quotation request: send the quotation form, write on WhatsApp +39 351 857 9082 or call +39 051 660 0608.
Each functional block—exciter, amplifier modules, splitter, combiner, unbalanced load, control and breakers—has its own enclosure and service access. The result is a transmitter that can be diagnosed, expanded and repaired module by module.

Main Features
- A module fault costs only a fraction of the power. Working CELL amplifiers remain on air while the failed module is isolated.
- The unbalanced load is sized to preserve redundancy. Each input is rated at 6,000 W, preventing reflected power from turning one module fault into a system shutdown.
- Every RF module is independently serviceable. CELL includes its own supply, fans, control, output filter and protections and can be tested outside the transmitter.
- The same building blocks scale from 5 to 100 kW. Shared modules, splitters, combiners and loads simplify upgrades, training and spare-parts management.
- Diagnostics remain granular at high power. Operators see current, voltage and temperature module by module, together with event and trend history.
Highlights
Modular RF architecture
- 5–50 kW from 2 to 20 CELL 2500 modules in a CORTEX system
- 100 kW by combining CORTEX units
- Splitters and combiners available for even and odd module counts
- Combiner loss below 0.1 dB, isolation above 26 dB and additive harmonic filtering above 12 dB in the documented multiport design
- Common CELL modules and service parts across the range
Audio, modulation and efficiency
- 85 dB typical SNR and 65 dB stereo separation
- Mono, stereo and MPX composite inputs with a 75 kHz soft limiter
- DRM and IBOC ready
- Up to 88% RF efficiency with adaptive DC-voltage and bias control
- 55–65 V, 9th-generation planar LDMOS with greater than 65:1 VSWR tolerance
- AES/EBU, AoIP, USB playback, Dynamic RDS and five-band processing available as options
Redundancy, control and protection
- HTML5 web interface, SNMP v1/v2c, e-mail and Telegram
- More than 100 working parameters monitored across the system
- 64,000-event log and one-month history chart
- Optional dual exciter with automatic changeover and test load
- Optional dual power supply on CELL modules
- Fast hardware protection and software derating for non-critical faults
How CORTEX keeps broadcasting after an RF module fault
The splitter feeds identical CELL amplifiers and the combiner adds their output. If one amplifier stops, the unbalanced load absorbs the resulting imbalance while the other modules remain connected to the antenna.
Each load input is rated at 6,000 W, while the documented unbalanced power at an input is normally around 1,300 W depending on the number of active modules. This margin prevents the load from overheating and reflecting power back toward the working amplifiers. It also avoids the double loss seen when a system removes the failed module and then derates all surviving modules.
The CELL 2500 — core RF building block
CELL 2500 is a self-contained 2U RF amplifier with its own plug-in supply, cooling, control, broadband output filter and protections. Its pre-driver requires less than 1 W, allowing a compact exciter to drive a large modular system.
The splitter input uses an attenuator/isolator so the exciter sees a stable 50-ohm load rather than the LDMOS inputs directly. A fault in a cable, splitter output or amplifier input therefore does not automatically create a VSWR shutdown at the exciter.
Power configurations
| Output power | RF architecture | Main building blocks |
|---|---|---|
| 5 kW | 2 × CELL 2500 | splitter, combiner, unbalanced load, exciter and control |
| 10 kW | 4 × CELL 2500 | 4-way splitter/combiner and corresponding load section |
| 25 kW | 10 × CELL 2500 | 10-way splitter/combiner, two 5-input load sections and rack |
| 50 kW | 2 × 25 kW amplifier sections | 3 dB hybrid coupler, 15 kW load, exciter and common control |
| 100 kW | combined CORTEX units | configured project by project |
Available single-system models: CORTEX 5k/2 · 7k5/3 · 10k/4 · 12k5/5 · 15k/6 · 17k5/7 · 20k/8 · 22k5/9 · 25k/10 · 30k/12 · 35k/14 · 40k/16 · 45k/18 · 50k/20.
See the modular system in detail
CELL module outside the rack

The module contains everything required for independent bench testing.
Multiport splitter and input isolator

One input is divided across the RF modules while the exciter remains presented with a matched load.
Multiport combiner

The same modular concept scales by changing the number of ports and amplifier modules.
Over-dimensioned unbalanced load

The load is physically sized to absorb module-fault imbalance without forcing the working modules off air.
Module-by-module web diagnostics

A remote operator can identify the affected module before dispatching service staff.
Dual exciter automatic changeover

The failed exciter is routed to a test load while the reserve unit goes on air.
Explore related TEKO products
- All FM Broadcast Transmitters — compare the three TEKO architectures
- AXON Low-Power FM Transmitters — compact complete transmitters and exciters
- SENSOR Medium-Power FM Transmitters — one SYNAPSE and one CELL in separate units
- CELL RF amplifiers and GYRUS RF amplifiers — RF-only building blocks for projects with an external exciter
- Request a high-power configuration
Standard equipment
- Required CELL amplifier modules, splitter, combiner and unbalanced load for the selected power
- SYNAPSE exciter, rack, breakers and control logic
- Local display on each RF module
- HTML5 web interface, SNMP v1/v2c, e-mail and Telegram notifications
- Module-level diagnostics, event log, history chart and weekly power scheduler
- RF, temperature, cooling and mains protection
- Tropicalized boards, ducted cooling and factory burn-in
Available options
- Dual exciter with automatic changeover and test load
- Second hot-plug power supply for CELL modules
- Touch-screen BRAIN WEB control unit
- High-performance stereo encoder and five-band audio processor
- Automatic audio-input changeover
- AES/EBU, AoIP, USB playback and Dynamic RDS with TMC
- External reference for SFN synchronization
- 192 kHz MPX digital composite input
- Japanese, OIRT and custom frequency bands
- Surge protection, delayed energization and uprated fans
Documents and engineering configuration
The exact CORTEX bill of materials depends on output power, mains distribution, RF output, redundancy and site layout. Use the model-specific technical sheet and project configuration rather than a generic family value for consumption, efficiency, rack size or connector dimensions.
Configure your CORTEX system
Provide the required licensed power, frequency, mains supply, redundancy target, site altitude and temperature, available rack space and preferred audio/control interfaces. TEKO will define the amplifier count, combining system, loads, exciter arrangement and options.